Welcome

Model 600 & 600v Multi-Purpose Valve Testing System

Our Model 600 Series clamp fixtures are designed to clamp and test valves, fittings and related pressure bearing parts between centers. Hydrostatic or pneumatic seat testing can be performed from both sides without removing the valve from the clamp fixture. The Model 600 Series test systems are best known as the “universal” valve testing system because of its adaptability to change seal plates very quickly and safely. Our patented Easy Out Seal Head Holders make changing seal plates for flanged, butt welded, socket welded, male and female threaded, bore sealing or special valve body end connections without the use of tooling or bolts.

The 600V Series roll frame systems are a Vertical Press style tester that can be designed as a ridged vertical clamp or the roll frame. The Roll Frame can be moved for easy valve loading and unloading then rolled back into position for testing. This system can be designed for dual valve testing where one valve is being tested while the other is being loaded.

Options for the Model 600 Systems Click here to see the options for the model 600 Systems

Diagrams

Features for the Model No. 600-6, 600-8, 600-12, 600-16 and 600-24 standard non-rotating flanged valve testing systmes. The Model 600 allows the operator to perform air and/or water testing on the same clamping fixture. Source air and water supplied by the customer.

Click Image to Enlarge

Specifications

Series 600-6 150 300 600 900 1500 2500
3,000 psi 1"      
  2"      
  3"      
  4"      
  6"      
10,000 psi 1"
  2"
  3"
  4"  
  6"      
Series 600-8 150 300 600 900 1500 2500
3,000 psi 1"      
  2"      
  3"      
  4"      
  6"      
10,000 psi 1"
  2"
  3"
  4"    
  6"      
Series 600-12 150 300 600 900 1500 2500
3,000 psi 1"      
  2"      
  3"      
  4"      
  6"      
10,000 psi 1"
  2"
  3"
  4"    
  6"      
Series 600-16 150 300 600 900 1500 2500
3,000 psi 1"      
  2"      
  3"      
  4"      
  6"      
10,000 psi 1"
  2"  
  3"    
  4"      
  6"        
  • Standard Features:
    • Air operated pump with 3,000 or 10,000 psi hydrostatic test circuit.
    • Air operated pump with 10,000 psi hydraulic clamp circuit.
    • 75, 100, 150, 200, & 300 ton hydraulic clamping.
    • One skid mounted clamp fixture.
  • Additional Options & Features
    • Air operated pump with 3,000 or 10,000 psi hydrostatic test circuit.
    • Air operated pump with 10,000 psi hydraulic clamp circuit.
    • 75, 100, 150, 200, & 300 ton hydraulic clamping.
    • One skid mounted clamp fixture.

Calder Testers, Inc.

9000 Monroe Houston,
Texas, 77061
Voice: (888) 704-TEST (8378)
Fax: (713) 944-2982

Calder Testers, (UK) Ltd.

8 Telford Court Morpeth,
Northumberland NE61 2DB United Kingdom
Tel: 44-167-050-5999
Fax: 44-167-051-7297

Specifications subject to change without notice www.caldertesters.com